Dome Lamp Switch Malfunction
- Ignition OFF, disconnect the harness connector at the E37F Dome/Reading Lamps - Front.
- Test for less than 5 Ω between the ground circuit terminal 6 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool Interior/Courtesy Lighting Master Switch parameter is Auto when the switch is in Door position.
- If the scan tool Interior/Courtesy Lighting Master Switch parameter is Cancel, test the dome lamp defeat signal circuit terminal 4 for short circuit to ground. If the circuit tests normal, replace the K9 Body Control Module.
- If the scan tool Interior/Courtesy Lighting Master Switch parameter is On, test the dome lamp on signal circuit terminal 5 for short circuit to ground. If the circuit tests normal, replace the K9 Body Control Module.
- Install a 3 A fused jumper wire between the dome defeat signal circuit terminal 4 and the ground circuit terminal 6. Verify the scan tool Interior/Courtesy Lighting Master Switch parameter is Cancel.
- If not the specified state, test the dome lamp defeat signal circuit for short circuit to voltage or an open/high resistance. If the circuit tests normal, replace the K9 Body Control Module.
- Install a 3 A fused jumper wire between the dome lamp on signal circuit terminal 5 and the ground circuit terminal 6. Verify the scan tool Interior/Courtesy Lighting Master Switch parameter is On.
- If not the specified state, test the dome lamp on signal circuit for short circuit to voltage or an open/high resistance. If the circuit tests normal, replace the K9 Body Control Module.
- If all circuits test normal, test or replace the E37F Dome/Reading Lamps - Front.
- Ignition OFF, disconnect the harness connectors at the appropriate dome lamp.
- Test for less than 5 Ω between the ground circuit terminal 6 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Connect a test lamp between the control circuit terminal 2 and the ground circuit terminal 6.
- Command the Courtesy Lamps ON and OFF with the scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K9 Body Control Module.
- If the test lamp is always OFF, test the control circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the K9 Body Control Module.
- If all circuits test normal, test or replace the E37F Dome/Reading Lamps - Front or E37M Dome/Reading Lamps - Middle.