LEMON Manuals: Even more car manuals for everyone
Home >> Saab >> 2011 >> 9-3X Standard >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Turbocharger System >> Repair Instructions >> Wastegate valve >> To remove

To remove

  1. Remove Turbo heat shield 
  2. Detach the inlet hose between the turbo and the air cleaner casing (A).
    Fig 1: Identifying Inlet Hose Between Turbo And Air Cleaner Casing
    G05053329Courtesy of SAAB-SCANIA OF AMERICA, INC.
  3. Remove the solenoid valve's hose (A) from the wastegate valve.
    Fig 2: Identifying Solenoid Valve's Hose, Crankcase Ventilation Hose And Solenoid Valve
    G05053330Courtesy of SAAB-SCANIA OF AMERICA, INC.
  4. Undo the solenoid valve (B) from the wastegate valve
  5. Move the solenoid valve and the inlet hose to the side.
  6. Remove the crankcase ventilation hose (C) from the camshaft cover and the turbo inlet.
  7. Remove the pipe connection for the crankcase ventilation (D).
  8. Undo the retaining clip (E) from the turbo control arm. Use tool 8394538.
    NOTE: The clip is not magnetic.
  9. Remove the wastegate valve from the turbo (F).