Bypass valve check, B207E/L: Checks
- Detach the vacuum hose from the bypass valve.
Courtesy of SAAB-SCANIA OF AMERICA, INC.
- Connect pressure/vacuum pump (30 14 883 Pressure/vacuum pump) and generate vacuum pressure in the valve.
Courtesy of SAAB-SCANIA OF AMERICA, INC.
- Check that the diaphragm is intact. If the diaphragm is damaged, the vacuum is relieved.
- Pump up an overpressure in the valve.
- Check that the diaphragm is intact. If the diaphragm is damaged, the overpressure is relieved.
- Detach the pump.
- Connect the vacuum hose.