LEMON Manuals: Even more car manuals for everyone
Home >> Saab >> 2010 >> 9-3X Standard >> Repair and Diagnosis >> Engine Mechanical >> Blowers, Superchargers & Turbochargers >> Turbocharger System >> Repair Instructions >> Wastegate valve >> To fit

To fit

  1. Fit the control rod to the control arm (E).
    Fig 1: Identifying Wastegate Valve, Wastegate Valve To Turbo, Retaining Clip And Camshaft Cover With Turbo Inlet
    G05053330Courtesy of SAAB-SCANIA OF AMERICA, INC.
  2. Fit the wastegate valve to the turbo (F)
    NOTE: Clip not magnetic.
  3. Fit the retaining clip (E). Use tool 8394538.
  4. Fit the pipe connection for the crankcase ventilation (D).
  5. Fit the crankcase ventilation hose for the camshaft cover and the turbo inlet (C).
  6. Fit the solenoid valve to the wastegate valve (B).
  7. Fit the solenoid valve hose to the wastegate valve (A).
  8. Fit the inlet hose between the turbo and the air cleaner casing.
    Fig 2: Identifying Solenoid Valve
    G05053329Courtesy of SAAB-SCANIA OF AMERICA, INC.
  9. Fit Turbo heat shield .