Recirculation Actuator Replacement
Recirculation Actuator Replacement
Removal Procedure
1. Remove the HVAC module assembly. Refer to HVAC Module Assembly Replacement (Service and Repair).
2. Remove the air inlet assembly.
3. Remove the screws from the air inlet assembly.
4. Remove the recirculation actuator screws.
5. Remove the recirculation actuator.
Installation Procedure
1. Install the recirculation actuator.
Caution: Refer to Fastener Caution (Fastener Caution).
2. Install the recirculation actuator screws and tighten to 1.9 Nm (17 in. lbs.).
3. Install the air inlet assembly.
4. Install the screws to the HVAC module assembly and tighten to 1.9 Nm (17 in. lbs.).
5. Install the HVAC module assembly. Refer to HVAC Module Assembly Replacement (Service and Repair).
6. Recalibrate the recirculation actuator on vehicles equipped with automatic climate control (C68). Refer to Actuator Recalibration (Testing and Inspection).