Hazard warning lights switch (25): Connection: Notes
The lead to the button is supplied 10.2 V via a BCM integrated resistor of 1.5 kO. Control module inputs are digital; voltage over 2V is interpreted as an open circuit while voltage lower than 2V is interpreted as closed.
The indicator lamp in the button is supplied battery voltage from BCM in order to light.