On-Board Diagnostics
WARNING: This page is about a different car, the 2003 Saab 9-3 and 2002 Saab 9-3. However, it is still accessible from the selected car via links, so may be relevant.
Type of diagnosis:
- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
Enable criteria
- Engine running. Main relay voltage exceeding 10V. Output is active.
Fault criteria
- Output voltage exceeding 2V for more than 1 s.
Dependents
- None
System reaction to a fault
- None
OK report
- Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
Fault handling: (For more information, see FAULT HANDLING III, OTHER EMISSION-RELATED COMPONENTS AND FUNCTION ).
- Type III.