Calibration Procedure
NOTIFICATION
Voltage drop
- Risk of irreparable damage to control unit
- Risk of damage to control unit
- Fault entries in the control unit
- Coding in the control unit is aborted
- Malfunctions in control unit, even during programming
→ Prior to disconnecting the control unit, switch off ignition and remove ignition key.
→ Ensure that the power supply is not interrupted during programming.
→ Connect a battery charger with a current rating of at least 90 A to the vehicle battery.
- Adhere strictly to the information provided under "Conditions for carrying out calibration"!
- Always carry out the "Calibration procedure" step-by-step until calibration is complete!
- Fit measured-value pickup > VAS 6918 - Quick-Clamping Unit on the relevant wheel.
- Connect the PIWIS Tester to the vehicle and start it. Switch on ignition using original remote control (hand-held transmitter).
- Apply the electric parking brake.
- Erase
the fault memory.
- 4.1 Select >>Levelling system/PASM <<>>Fault memory <<>>Erase fault memory << in the control unit overview.
- 4.2 Follow the instructions on the Porsche System Tester.
- Perform Height sensor system component test.
- 5.1 Select >>Maintenance/repairs << >>Height sensor system component test << in the menu.
- 5.2 Follow the instructions on the Porsche System Tester.
- Perform height sensor calibration.
- 6.1 Select >>Maintenance/repairs << >>Height sensor calibration << in the menu.
- 6.2 Follow the instructions on the Porsche System Tester.
Information
Check the following at the height measuring point on the front axle:
- Lower edge of the wing is covered by the front lid.
- Only measure the height on the front axle when the front lid is open.
- Determine the actual value for the height of the vehicle body at the measuring points.
- 7.1 When determining the height of the vehicle body, the height is measured from the lower edge of the wing to the upper edge of the measured-value pickup, dimension X .
- 7.2 Then add the radius of the measured-value pickup 32.5
mm to this measured dimension X
.
Sample calculation:
Measured dimension X = 430 mm; measured-value pickup radius = 32.5 mm
X + measured-value pickup radius = vehicle body height
430 mm + 32.5 mm = 462.5 mm
- 7.3 Enter the determined values in the PIWIS Tester .
- If an implausible value is entered (actual value is not accepted by the PIWIS Tester ), please refer to the information under: "Procedure: Measured actual value is not accepted".
- Complete the diagnostic session (only for steel springs)
- 8.1 Select >>Drive links/checks << >>Completion of height sensor calibration << in the menu.
- 8.2 Follow the instructions on the Porsche System Tester.
- 8.3 When calibration is completed successfully, >>Result << >>Function completed << is displayed!
When calibration is complete, the vehicle does not adjust automatically to Normal Level. The height values can only be checked after test-driving the vehicle.