LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2023 >> Taycan Base >> Repair and Diagnosis >> Suspension >> Electronic Suspension >> 43 Leveling System, Air Suspension, Damper Control 2.0L -- Y1A - TAYCAN (Y1A) >> WM, 430117 Bleeding And Filling The Levelling System >> Bleeding And Filling The Levelling System >> Filling Air In One Air Spring

Filling Air In One Air Spring

WARNING: Wheel bearing housing raised incorrectly 
  • Risk of crushing 
  • Risk of damage to components 

    → Wear personal protective gear.

    → Do not raise the wheel suspension higher than the normal vehicle position (vehicle resting on wheels).

Information 

The pictures shown in this document may differ from the original.

Information 

Preconditions for filling an air spring/the air suspension system

  1. Applies only to rear air suspension bellows:  Lift lower trailing arm before filling it and align the air spring in the lower trailing arm.

    > 434319 REMOVING AND INSTALLING AIR SUSPENSION BELLOWS  - information on "Installing".

    1. 1.1 Position the air suspension bellows -1-  so that the cable -2-  on the electric plug connection is located in the recess -3-  on the trailing arm.
      G15553095Courtesy of PORSCHE CARS NORTH AMERICA, INC.

      Alignment of air spring bellows in lower trailing arm

    2. 1.2 Lift the lower trailing arm -2-  using > VAS 6931 - engine and gearbox jack  until the air suspension bellows -1-  are resting on the lower trailing arm -Arrow-  .
      G15553096Courtesy of PORSCHE CARS NORTH AMERICA, INC.

      Air suspension bellows in lower trailing arm

    3. 1.3 Check that the air spring in the lower trailing arm is aligned correctly.
  2. Fill air into one air spring.
    1. 2.1 Connect the PIWIS Tester  to the vehicle and switch it on.
    2. 2.2 Establish operational readiness/switch on ignition.
    3. 2.3 Start diagnostics.
    4. 2.4 Select "Chassis control PASM"  control unit.
    5. 2.5 Select the "Maintenance/repairs"  tab.
    6. 2.6 Select the menu item "Replacement work on the air spring system"  and press F12 to continue.
    7. 2.7 Select the "Replacement of an air spring"  function and press F12 to continue.
    8. 2.8 Select the "Filling an air spring"  function and press F12 to continue.
    9. 2.9 Follow the other instructions on the Tester.