Remove Pressure Switch
Information
- For all work on the air-conditioning system that necessitates opening the refrigerant system, the system contents must first be disposed of in accordance with regulations.
- Dirt and moisture must be kept out of the air-conditioning system pipes and hoses.
- Cleanliness must be ensured during all work.
- System components must never be cleaned on the inside with hot steam.
- Only use nitrogen for cleaning.
- When replacing a component, all openings must be closed off using suitable stoppers immediately after opening the system.
- Remove pressure switch -1- .
Pressure switch
- 1.1 Release and disconnect cable plug -2- .
- 1.2 Unscrew and remove pressure switch -1- .
- 1.3 Close off line opening using a suitable stopper.