Removing Blower Regulator
NOTIFICATION
Voltage peaks
- Risk of damage to electrical load or to the control unit
→ Remove the ignition key and switch off load before disconnecting or removing load.
- Remove blower regulator -1- .
Fan control
- 1.1 Release and disconnect electric plug connections -2- .
- 1.2 Unscrew and remove screws -3- .
- 1.3 Remove fan control -1- .