Removing Condenser
Information
- For all work on the air-conditioning system that necessitates opening the refrigerant system, the system contents must first be disposed of in accordance with regulations.
- Dirt and moisture must be kept out of the air-conditioning system pipes and hoses.
- Cleanliness must be ensured during all work.
- System components must never be cleaned on the inside with hot steam.
- Only use nitrogen for cleaning.
- When replacing a component, all openings must be closed off using suitable stoppers immediately after opening the system.
- Disconnect refrigerant lines -1 and 2-
from the condenser.
Refrigerant lines on condenser
- 1.1 Unscrew and remove screws -3- .
- 1.2 Disconnect refrigerant lines -1 and 2- from the condenser.
- 1.3 Close off refrigerant lines using suitable stoppers.
- 1.4 Release and disconnect electric plug connection -4- .
- Remove condenser -1-
.
Condenser
- 2.1 Loosen mountings -2- (-arrows A- ).
- 2.2 Remove condenser -1- by pulling it upwards -arrow B- .