Subsequent Work
WARNING: This page is about a different car, the 2021 Porsche Macan, 2020 Porsche Macan, and 2019 Porsche Macan. However, it is still accessible from the selected car via links, so may be relevant.
Information
Calibrate the vehicle after installing or replacing the combination sensor.
- Calibration must only be performed when the vehicle is positioned horizontally and the brake is not actuated.
- Install centre console.
- Connect the battery and carry out instructions after connecting the battery.
> 2X00IN - WORK INSTRUCTIONS AFTER DISCONNECTING THE BATTERY
- Calibrate the combination sensor (includes lateral and axial acceleration sensor) with PIWIS Tester
.
Select PSM >> Maintenance/repairs >> PSM - sensor calibration >> Calibrate - axial acceleration sensor and Calibrate lateral acceleration sensor in the menu.