LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2023 >> Macan Base >> Repair and Diagnosis >> Suspension >> Electronic Suspension >> 43 Leveling System, Air Suspension, Damper Control 2.0L -- 95B - MACAN (95B) >> WM, 430115 Calibrating The Levelling System >> Calibrating The Levelling System >> Calibration Procedure

Calibration Procedure

NOTIFICATION 

Voltage drop 

  1. Fit measured-value pickup > VAS 6918 - Quick-Clamping Unit  on the relevant wheel.
  2. Connect the PIWIS Tester  to the vehicle and start it. Switch on ignition using original remote control (hand-held transmitter).
  3. Apply the electric parking brake.
  4. Erase  the fault memory.
    1. 4.1 Select >>Levelling system/PASM  <<>>Fault memory  <<>>Erase fault memory  << in the control unit overview.
    2. 4.2 Follow the instructions on the Porsche System Tester.
  5. Perform Height sensor system component test. 
    1. 5.1 Select >>Maintenance/repairs  << >>Height sensor system component test  << in the menu.
    2. 5.2 Follow the instructions on the Porsche System Tester.
  6. Perform height sensor calibration. 
    1. 6.1 Select >>Maintenance/repairs  << >>Height sensor calibration  << in the menu.
    2. 6.2 Follow the instructions on the Porsche System Tester.

    Information 

    Check the following at the height measuring point on the front axle: 

    • Lower edge of the wing is covered by the front lid. 
    • Only measure the height on the front axle when the front lid is open. 
  7. Determine the actual value for the height of the vehicle body at the measuring points.
    1. 7.1 When determining the height of the vehicle body, the height is measured from the lower edge of the wing to the upper edge of the measured-value pickup, dimension .
    2. 7.2 Then add the radius of the measured-value pickup 32.5  mm to this measured dimension .

      Sample calculation: 

      Measured dimension X = 430 mm; measured-value pickup radius = 32.5 mm

      X + measured-value pickup radius = vehicle body height 

      430 mm + 32.5 mm = 462.5 mm

    3. 7.3 Enter the determined values in the PIWIS Tester  .
    4. If an implausible value is entered (actual value is not accepted by the PIWIS Tester  ), please refer to the information under: "Procedure: Measured actual value is not accepted".
  8. Complete the diagnostic session (only for steel springs) 
    1. 8.1 Select >>Drive links/checks  << >>Completion of height sensor calibration  << in the menu.
    2. 8.2 Follow the instructions on the Porsche System Tester.
    3. 8.3 When calibration is completed successfully, >>Result  << >>Function completed  << is displayed!

    When calibration is complete, the vehicle does not adjust automatically to Normal Level. The height values can only be checked after test-driving the vehicle.