Installing Valve Unit
Information
Check the following before installing the air line:
- Check that the cutting ring -1- and Voss threaded joint -2- are on the air line -3- (not relevant if the air spring bellows was replaced and the Voss threaded joint that is pre-fitted on the air spring bellows is used).
- Check that the air line is fitted correctly.
Checking air line
Only one marking -1- on the air line should be visible.
Pull the air line briefly against the insertion direction. If it cannot be pulled out, the air line is fitted correctly.
Checking that air line is fitted correctly
- Installation is performed in reverse order. Pay particular attention to the following:
- 1.1
Screws securing valve unit to holder:
> Tightening torque 4 Nm (3 ftlb.)
- 1.2
Air line to valve unit (4 mm air connection):
> Tightening torque 2.3 Nm (1.7 ftlb.)
- 1.3
Air line to valve unit (6 mm air connection):
> Tightening torque 3.5 Nm (2.6 ftlb.)
- 1.4
Stone guard for valve unit:
> Tightening torque 9 Nm (6.5 ftlb.)
- 1.1
Screws securing valve unit to holder: