Technical Values
WARNING: This page is about a different variant/trim than selected.
| Location | Description | Type | Basic value | Tolerance 1 | Tolerance 2 |
|---|---|---|---|---|---|
| Double screw for additional coolant pump (run-on) | M6 x 14/M6 x 14 | Tightening torque | 9 Nm (6.5 ftlb.) | ||
| Screws securing additional coolant pump (run-on) to holder | Tightening torque | 1.5 Nm (1 ftlb.) | |||
| Screws for coolant pipe on left cylinder bank | Tightening torque | 9 Nm (6.5 ftlb.) | |||
| Screw for chain housing cover on cylinder bank 1 | M6 x 22 (8 ea.)/replace, observe specified tightening sequence | Tightening torque | 9 Nm (6.5 ftlb.) | ||
| Screw for chain housing cover on cylinder bank 2 | M6 x 22 (7 ea.)/replace, observe specified tightening sequence | Tightening torque | 9 Nm (6.5 ftlb.) | ||
| Fastening screw for high-pressure fuel line | Replace | tightening torque | 8 Nm (5.9 ftlb.) | ||
| Fastening screw for high-pressure fuel line | final tightening torque | 45° | |||
| Union nut for fuel line | Coat thread on union nuts with Microgleit DF 977S. Observe drying time of at least 5 minutes before fitting. | tightening torque of | 10 Nm (7.4 ftlb.) | ||
| Union nut for fuel line | Coat thread on union nut with Microgleit DF 977S. Observe drying time of at least 5 minutes before fitting. | Torque angle | 60° |