Technical Values
WARNING: This page is about a different variant/trim than selected.
| Location | Description | Type | Basic value | Tolerance 1 | Tolerance 2 |
|---|---|---|---|---|---|
| Fastening screws for high-pressure pump | M8 x 25 | Initial tightening | 20 Nm (14.8 ftlb.) | ||
| Fastening screws for high-pressure pump | Final tightening | + 45° | |||
| Low-pressure fuel line distributor | Coat thread on union nuts with Microgleit DF 977S. Observe drying time of at least 5 minutes before fitting. | Tightening torque | 8 Nm (5.9 ftlb.) | ||
| Low-pressure fuel line distributor | Coat thread on union nuts with Microgleit DF 977S. Observe drying time of at least 5 minutes before fitting. | Torque angle | 60° | ||
| Union nut for fuel line | Coat thread on union nuts with Microgleit DF 977S. Observe drying time of at least 5 minutes before fitting. | tightening torque of | 10 Nm (7.4 ftlb.) | ||
| Union nut for fuel line | Coat thread on union nut with Microgleit DF 977S. Observe drying time of at least 5 minutes before fitting. | Torque angle | 60° |