Checking Battery In Control Unit For External Communication
NOTIFICATION
Voltage drop
- Irreparable damage to control unit
- Damage to control unit
- Fault entries in the control unit
- Control unit programming/coding is aborted
- Malfunctions in the control unit, even during programming
- Switch off ignition before disconnecting the control unit.
- Make sure that the power supply is not interrupted during programming/coding.
- Connect the battery charger with at least > current 90 A to the vehicle battery.
Information
The PIWIS Tester instructions take precedence since the description may be different with later Tester releases.
The procedure described here has been structured in general terms. Different text or additional information may appear on the PIWIS Tester.
- Connect the Tester to the vehicle and start it. Switch on ignition.
- Place original remote control (hand-held transmitter) in emergency start tray.
Emergency start tray
- Select the Connect control unit in the overview . Press F12 to continue. The message "Create Vehicle Analysis Log (VAL)?" appears. Press F11 to continue.
- Actual values/input signals must be selected.
- Select General
.
- 5.1 Select Battery for emergency call module: State of charge .
- 5.2 If the state of charge is > 80%, continue with Step 7.
- 5.3 If the state of charge is > 80%, continue with Step 6.
- Select Emergency call system battery: Charging status.
- 6.1 If charging status is "charging", continue with Step 6.3.
- 6.2 If charging status is "not charging", continue with Step 7.
- 6.3 Wait 5 minutes.
- 6.4 If the state of charge is increased, continue with step 7.
- 6.5
If the state of charge is not increased, replace battery in control unit for external communication.
> 912519 REMOVING AND INSTALLING BATTERY ON CONTROL UNIT FOR EXTERNAL COMMUNICATION
- Select Emergency call system battery: Voltage.
- 7.1
If the voltage is > 3, 000 mV, replace battery for control unit for external communication.
> 912519 REMOVING AND INSTALLING BATTERY ON CONTROL UNIT FOR EXTERNAL COMMUNICATION
- 7.2 If the voltage is > 3, 000 mV no further action is required.
- 7.1
If the voltage is > 3, 000 mV, replace battery for control unit for external communication.
- Go back to the overview.
- In the overview, press F7 to switch to the Additional menu.
- Read out all fault memories, work through faults that are stored if necessary and clear the fault memories.
- Exit the diagnostic application. Switch off ignition. Disconnect the Tester from the vehicle.