Installing Expansion Valve 2
NOTE:
NOTIFICATION
Opened refrigerant system for repairs.
Opened refrigerant system for repairs.
- Risk of moisture getting into the refrigerant system.
- Risk of contaminating the refrigerant circuit.
- Risk of saturation and irreparable damage to desiccator.
- Irreparable damage to the desiccator can damage the compressor and evaporator.
→ After opening the refrigerant circuit, close off the refrigerant lines/connections immediately using the relevant stoppers. To avoid contaminating the refrigerant circuit, the stoppers for the different refrigerants must be stored and used separately.
→ The desiccator must be replaced if the air humidity is high and if the refrigerant circuit is left open for a long time.
- Install expansion valve 2 -1-
.
- 1.1 Replace O-rings on refrigerant lines -3 and 6- .
- 1.2 Position expansion valve 2 -1- and attach refrigerant line -6- .
- 1.3
Insert screws in holder for expansion valve 2 and tighten -5-
.
> Tightening torque 8 Nm (6 ftlb.)
- 1.4
Fit and tighten screw -4-
.
> Tightening torque 8 Nm (6 ftlb.)
- 1.5 Push on refrigerant line -3- .
- 1.6
Fit and tighten screw -2-
.
> Tightening torque 8 Nm (5.9 ftlb.)
Expansion valve 2
- Secure electric wire harness -1- .
- Install -1- bulkhead.