Installing Front Roof Outer Section
Information
- Before final assembly, make sure you fully understand all the work steps involved and carry out a trial assembly without applying adhesive.
- The bonding process can only be carried out reliably when a smooth and swift sequence of operations is guaranteed.
- Do not begin bonding work until all materials and tools necessary for later repair work are available.
- Install front roof outer section and check that it fits perfectly.
- Apply adhesive evenly on the joint area of the body.
> 5X00IN21 Working with body structural adhesive
> Application depth 0.5 mm
Adhesive in joint area
- Apply adhesive evenly on front roof outer section -A and B-
.
> 5X00IN21 Working with body structural adhesive
> Application depth 0.5 mm
- 3.1 Also apply an adhesive bead of sealant all around the bonding surface. > Application depth 3 mm
Adhesive
- Install front roof outer section.
- 4.1 Rivet in front roof outer section -1-
using > flow-form rivet 97A.008.473.00
.
> 5X00IN REPLACING PUNCH RIVETS AND PENETRATED JOINTS
Front roof outer section
- 4.2 Apply a full weld on front roof outer section -1- (-A- ).
Front roof outer section
- 4.1 Rivet in front roof outer section -1-
using > flow-form rivet 97A.008.473.00
.