Removing Refrigerant Line Between Condenser And Desiccator (Section From Condenser To Check Valve)
NOTE:
Opened refrigerant system for repairs.
- Risk of moisture getting into the refrigerant system.
- Risk of contaminating the refrigerant circuit.
- Risk of saturation and irreparable damage to desiccator.
- Irreparable damage to the desiccator can damage the compressor and evaporator.
→ After opening the refrigerant circuit, close off the refrigerant lines/connections immediately using the relevant stoppers. To avoid contaminating the refrigerant circuit, the stoppers for the different refrigerants must be stored and used separately.
→ The desiccator must be replaced if the air humidity is high and if the refrigerant circuit is left open for a long time.
- Remove refrigerant line -1-
.
- 1.1 Unscrew screw -2- .
- 1.2 Disconnect refrigerant line -1- from condenser -3- .
- 1.3 Unclip clip -4- .
- 1.4 Unscrew screw -5- .
- 1.5 Pull refrigerant line -1- off the block at the threaded joint -6- and remove it.
- 1.6 Close off line connections using suitable stoppers.
Refrigerant line between condenser and desiccator