Removing Refrigerant Line Between Compressor And Condenser (Section From Shut-Off Valve To Condenser)
NOTE:
Opened refrigerant system for repairs.
- Risk of moisture getting into the refrigerant system.
- Risk of contaminating the refrigerant circuit.
- Risk of saturation and irreparable damage to desiccator.
- Irreparable damage to the desiccator can damage the compressor and evaporator.
→ After opening the refrigerant circuit, close off the refrigerant lines/connections immediately using the relevant stoppers. To avoid contaminating the refrigerant circuit, the stoppers for the different refrigerants must be stored and used separately.
→ The desiccator must be replaced if the air humidity is high and if the refrigerant circuit is left open for a long time.
- Loosen refrigerant line -1-
from shut-off valve -2-
.
- 1.1 Unclip clip -3- .
- 1.2 Unscrew screw -4- .
- 1.3 Pull out refrigerant line -1- .
- 1.4 Close off line connections using suitable stoppers.
Refrigerant line between compressor and shut-off valve
- Disconnect refrigerant line -1-
from condenser -2-
.
- 2.1 Unscrew screw -3- .
- 2.2 Disconnect and remove refrigerant line -1- .
- 2.3 Close off line connections using suitable stoppers.
Refrigerant line between compressor and condenser