Installing Refrigerant Line Between Compressor And Condenser (Section From Shut-Off Valve To Condenser)
NOTE:
Opened refrigerant system for repairs.
- Risk of moisture getting into the refrigerant system.
- Risk of contaminating the refrigerant circuit.
- Risk of saturation and irreparable damage to desiccator.
- Irreparable damage to the desiccator can damage the compressor and evaporator.
→ After opening the refrigerant circuit, close off the refrigerant lines/connections immediately using the relevant stoppers. To avoid contaminating the refrigerant circuit, the stoppers for the different refrigerants must be stored and used separately.
→ The desiccator must be replaced if the air humidity is high and if the refrigerant circuit is left open for a long time.
- Install refrigerant line -1-
.
- 1.1 Replace O-rings on refrigerant line -1- .
- 1.2 Position refrigerant line -1- and push it onto the condenser -2- .
- 1.3 Fit and tighten screw -3-
.
> Tightening torque 8 Nm (6 ftlb.)
Refrigerant line between compressor and condenser
- Secure refrigerant line -1-
to shut-off valve -2-
.
- 2.1 Push refrigerant line -1- onto the shut-off valve.
- 2.2 Fit and tighten screw -4-
.
> Tightening torque 8 Nm (6 ftlb.)
- 2.3 Clip in clip -3- .
Refrigerant line between compressor and shut-off valve