Installing Refrigerant Line From Condenser To Condenser
- Danger of freezing
→ Avoid contact with refrigerant.
→ Wear personal protective gear.
→ Observe the safety regulations for working on air-conditioned vehicles and handling refrigerant.
→ Observe the safety regulations for extraction and filling systems.
→ Observe the instructions for repairing air-conditioning systems and storing spare parts.
- Risk of moisture getting into the refrigerant system.
- Risk of contaminating the refrigerant circuit.
- Risk of saturation and irreparable damage to desiccator.
- Irreparable damage to the desiccator can damage the compressor and evaporator.
→ After opening the refrigerant circuit, close off the refrigerant lines/connections immediately using the relevant stoppers. To avoid contaminating the refrigerant circuit, the stoppers for the different refrigerants must be stored and used separately.
→ The desiccator must be replaced if the air humidity is high and if the refrigerant circuit is left open for a long time.
- Install refrigerant line -1-
.
- 1.1 Replace O-rings on refrigerant line -1- .
- 1.2 Position refrigerant line -1- .
- 1.3 Screw in and tighten screws -2-
.
> Tightening torque 8 Nm (6 ftlb.)
Refrigerant line from condenser to condenser