Subsequent Work
- Perform potential equalization measurement.
> 2X00IN PERFORMING POTENTIAL EQUALISATION MEASUREMENT (FOUR-WIRE MEASUREMENT)
- Install high-voltage distributor mounting.
> 271719 REMOVING AND INSTALLING HIGH-VOLTAGE DISTRIBUTOR MOUNTING
- Perform insulation measurement.
- See Starting the high-voltage system and Test log for starting the high-voltage system.
> WM, 2X00IN ACTIVATING/STARTING HIGH-VOLTAGE SYSTEM
and
- Start the high-voltage system.
- Add refrigerant.
- Perform function test for interior cooling and high-voltage battery cooling using the PIWIS Tester.
- 6.1 PIWIS Tester must be connected to the vehicle and switched on.
- 6.2 Establishing operational readiness/Ignition on.
- 6.3 Start diagnostics.
- 6.4 Select Thermal management control unit .
- 6.5 Select Maintenance/repairs
- 6.6 Select the menu item Teach electric air-conditioning compressor and press F12 to continue.
- 6.7 Follow the instructions on the Tester.
- If the electric air-conditioning compressor was replaced: Perform automatic programming