Home >> Porsche >> 2021 >> Taycan Turbo S >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> 87 Air Conditioning -- Y1A - TAYCAN (Y1A) >> WM, 87201929 Removing And Installing Servo Motor For Rear Left Air Distribution >> Subsequent Work

Subsequent Work

  1. Install centre console trim (centre) at the bottom.

    > 68141907 REMOVING AND INSTALLING CENTRE CONSOLE TRIM (CENTRE) AT THE BOTTOM

  2. Install driver's seat.

    > 720119 REMOVING AND INSTALLING FRONT SEAT

    Information 

    If servo motors were replaced or work was performed on the flap mechanism, the end positions of the servo motors must be taught.

    Information 

    The terms "Ignition on" and "Starting engine" are re-defined for fully electric vehicles (battery electric vehicles - BEV).

    Establishing operational readiness/Ignition on: 

    Prerequisites for establishing operational readiness: High-voltage battery is sufficiently charged, remove vehicle charging cable from the vehicle charge port, put driver's key in the emergency start tray.

    Establishing operational readiness automatically: Get into the vehicle and close the driver's door. The driver's key is recognized inside the vehicle. Operational readiness is established.

    Establishing operational readiness manually: Press Start/Stop switch. The driver's key is recognized inside the vehicle. Operational readiness is established.

    Establishing operational readiness/Starting engine: 

    Establish operational readiness and engage transmission range. The vehicle is now ready to drive and can be moved.

    Ending operational readiness/Switching off ignition 

    Ending operational readiness automatically: Get out of the vehicle with the driver's key and close the driver door. The driver's key is no longer detected outside the vehicle. Operational readiness ends.

    Ending operational readiness manually: Press Start/Stop switch until the instrument cluster is switched off.

    Ending driving readiness/Stopping engine 

    Vehicle is stationary: Press the button on the instrument cluster. The vehicle is parked.

  3. Teach end positions of servo motors.
    1. 3.1 Connect the PIWIS Tester  to the vehicle and switch on the PIWIS Tester  .
    2. 3.2 Establish operational readiness.
    3. 3.3 Start diagnostics.
    4. 3.4 Select "Air conditioning  " control unit.
    5. 3.5 Select the "Maintenance/repairs  " tab.
    6. 3.6 Select the "Teach and check flap servo motors  " menu item and press F12 to continue.
    7. 3.7 Follow the instructions on the Tester.