Removing Servo Motor For Front Left Temperature Mixing Flap
NOTE:
Voltage peaks
- Risk of damage to electrical load or to the control unit
→ Switch off ignition and keep transmitter key outside of the transmission range (at least 5 m).
→ Switch off electrical loads before disconnecting or removing them.
- Remove holder for air conditioning control unit -1-
.
- 1.1 Unscrew screws -2- and remove holder for air conditioning control unit -1- .
Holder for air conditioning control unit
- Remove servo motor for front left temperature mixing flap -1-
.
- 2.1 Release and disconnect electric plug connection -2- .
- 2.2 Unscrew and remove screws -3- .
- 2.3 Remove servo motor for front left temperature mixing flap -1- .
Servo motor for front left temperature mixing flap