Preliminary Work
Information
- Four flushing routines must be performed in order to clean the complete refrigerant circuit on the Taycan.
- The four flushing routines are performed automatically one after the other using the Tester.
- Some flushing routines cannot be used.
- The first flushing routine cleans the refrigerant circuit between the charging valves and evaporator.
- The second flushing routine cleans the refrigerant circuit between the charging valves and evaporator (chiller).
- The third flushing routine (if additional equipment "heat pump" is installed) cleans the refrigerant circuit between the charging valves and all three shut-off valves (EAV2, EAV3 and EAV5).
- The fourth flushing routine cleans the refrigerant circuit between the charging valves and condenser.
- The necessary flushing adapters must be installed before starting the flushing routines.
> 8X00IN OVERVIEW OF ADAPTERS FOR CLEANING THE REFRIGERANT CIRCUIT
- All information and procedures in the PIWIS Tester take precedence.
- Drain refrigerant.
- Remove internally damaged (seized up) air-conditioning compressor.
> 873419 REMOVING AND INSTALLING ELECTRIC AIR-CONDITIONING COMPRESSOR .
- If the air-conditioning compressor is seized up: Install new condenser.
- Remove desiccator.
- Remove check valve.