Measurement 6

WARNING: Incorrect handling of high-voltage components 
  • Electric shock 
  • Short circuit 
  • Fire 
  • Explosion 

    → Only appropriately trained and authorised persons are permitted to work on high-voltage vehicles and components.

    → Required qualification: High voltage technician or high voltage expert.

    → Observe national requirements and legislation for this work.

    → Always use insulated tools, e.g. > VAS 6883 - Insulated Tool Set  when working on these components.

    → Observe general warning notes for working on the high-voltage system.

    > 2X00IN GENERAL WARNING NOTES FOR WORKING ON THE HIGH-VOLTAGE SYSTEM 

Preliminary work for measurement 6 

(Check: High-voltage distributor, electric drive motor, front power electronics)

  1. Connect high-voltage test adapter > VAS 6558/9-6A - High-voltage test adapter  to high-voltage distributor (passenger compartment heater connection). Leave the second connection open.
    G15552175Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Measurement 6

  2. Perform measurement 6.
    1. 2.1 Setpoint value ≥ 1.1 MOhm 
  3. Evaluate measured result 
    1. 3.1 If the measured value is within  the setpoint value range, continue with measurement 11  .
    2. 3.2 If the measured value is outside  of the setpoint value range, continue with measurement 7  .