Measurement 4
- Electric shock
- Short circuit
- Fire
- Explosion
→ Only appropriately trained and authorised persons are permitted to work on high-voltage vehicles and components.
→ Required qualification: High voltage technician or high voltage expert.
→ Observe national requirements and legislation for this work.
→ Always use insulated tools, e.g. > VAS 6883 - Insulated Tool Set when working on these components.
→ Observe general warning notes for working on the high-voltage system.
> 2X00IN GENERAL WARNING NOTES FOR WORKING ON THE HIGH-VOLTAGE SYSTEM
Preliminary work for measurement 4
(Check: High-voltage distributor, passenger compartment heater, electric drive motor, front power electronics, high-voltage line from high-voltage distributor to high-voltage charger)
- Remove luggage compartment liner.
> 501919 REMOVING AND INSTALLING LUGGAGE COMPARTMENT LINER - on "Removing"
- Release and disconnect high-voltage line (from high-voltage charger to charging socket).
High-voltage line from high-voltage charger to charging socket
- Release and disconnect high-voltage line (from high-voltage distributor to high-voltage charger) at the high-voltage charger.
High-voltage line from high-voltage distributor to high-voltage charger
- Connect high-voltage test adapter > VAS 6558/9-6A - High-voltage test adapter
at the high-voltage distributor (passenger compartment heater connection).
Measurement 4
- Perform measurement 4.
- 5.1 Setpoint value ≥ 1.1 MOhm
- Evaluate measured result
- 6.1 If the measured value is within the setpoint value range, continue with measurement 10 .
- 6.2 If the measured value is outside of the setpoint value range, continue with measurement 5 .