Technical Values
| Location | Description | Type | Basic value | Tolerance 1 | Tolerance 2 |
|---|---|---|---|---|---|
| hydraulic leak test | Absolite pressure | Pressure | 2000 mbar | ||
| Hydraulic leak test | Pressure difference | Pressure | 40 mbar | ||
| hydraulic leak test | Holding time | Time | 120 s | ||
| Vacuum test | Absolute pressure | Pressure | + 40 mbar | ||
| Vacuum test | Holding time | Time | 120 s | ||
| Vacuum test | Vacuum time | Time | 240 s | ||
| Vacuum test | Pressure difference | Pressure | 40 mbar | ||
| Filling quantity | Coolant in grams | Mass | 7000 g | ||
| Bleeding | Absolute pressure | Pressure | 1800 mbar |