Removing Valve Unit
- Remove heat protection panel -1-
at the bottom from the bolts and press it aside slightly.
Heat protection panel mounting
- Release and disconnect electric plug connection -2-
on the valve unit -1-
.
Electric plug connection on the valve unit
Information
The cutting ring -1- and Voss threaded joint -2- must remain on the air line -3- .
Air line
- Remove air lines on valve unit -1-
.
Mounting for air lines on valve unit
- 3.1 Unscrew Voss threaded joints -2 and 3- and pull off air lines.
- Remove valve unit -1-
.
Mounting for valve unit
- 4.1 Unscrew fastening screws -2- .