Protective Measures And Rules Of Behaviour: Notes
Information
Protective measures and rules of behaviour
Assembly work must only be carried out by trained staff.
Carry out tests only using the > 9900 - PIWIS Tester 3 diagnostic unit; do not use test lamps, voltmeters or ohmmeters.
Avoid contact with grease, solvents, cleaning agents or liquids.
Do not expose to temperatures above 90°C.
Keep the deployment area of the blow-out opening clear; e.g. do not hang test devices over the steering wheel. When carrying, hold the airbag with the blow-out direction facing away from the body. Set the airbag unit down with the blow-out opening facing upwards.
Electrostatic charge: In general, wear appropriate work clothing and footwear.
Do not remove the short-circuit spring of the plug contacts.
An airbag unit must never be connected incorrectly to electric power sources (danger of ignition). Only use testers prescribed by the manufacturer.
During installation/removal or work on the vehicle involving vibrations: switch off ignition, disconnect and cover the negative terminal of the battery, wait 1 minute and only then should you disconnect the plug connection.
Transport: in transport packaging. Never in the passenger compartment!
Storage in the workshop: Max. 10 kg (=> 100 driver or 50 passenger airbags); protect against theft!
The airbag/belt tensioner unit must be installed immediately after removal from the transport container.
If work is interrupted, the airbag/belt tensioner unit must be stored in the transport container again.
Leaving the airbag/belt tensioner unit unsupervised is not permitted.