MEASUREMENT IN HV DC CIRCUIT AS PER Service Information
WARNING: This page is about a different variant/trim than selected.
Perform function test on voltage tester at the jump-start terminal on the vehicle or at the starter battery using a reference voltage.
Measured voltage: __________ V (Setpoint value: 10.5 V to 14.5 V)
| Measurement for de-energizing the system | Additional measurement | ||
|---|---|---|---|
| Measurement 1: Voltage measurement at HV positive (+) to HV negative (-) | V | V | Setpoint: < 5 V |
| Measurement 2: Voltage measurement at HV positive (+) to body ground (shield) | V | V | Setpoint: < 5 V |
| Measurement 2: Voltage measurement at HV negative (-) to body ground (shield) | V | V | Setpoint: < 5 V |
Perform function test on voltage tester at the jump-start terminal on the vehicle or at the starter battery using a reference voltage.
Measured voltage: __________V (Setpoint value: 10.5 V to 14.5 V)
Absence of electric charge verified manually: YES □ NO □