Installing Supply Line - V6 Turbo (Section From Engine To High-Pressure Pump)
- Installation is performed in reverse order. Pay particular attention to the following:
Make sure that locks on connections engage securely.
Coat thread on union nut with Microgleit DF 977S. Observe drying time of at least 5 minutes before fitting!
Union nut > tightening torque of 10 Nm (7.4 ftlb.) .
Fastening screw on holder for camshaft controller actuator > Tightening torque 9 Nm (6.6 ftlb.) .
Fastening nuts for supply line > Tightening torque 9 Nm (6.6 ftlb.) .
Fastening screw for holder > tightening torque 8 Nm (5.9 ftlb.) .
Fastening screws for heat shield on high-pressure pump, M6 x 25 >.
Fastening screws for heat shield on high-pressure pump, M6 x 12 >.