Replacing Control Unit For Memory Seat Adjustment
NOTIFICATION
Voltage drop
- Irreparable damage to control unit
- Damage to control unit
- Fault entries in the control unit
- Control unit programming/coding is aborted
- Malfunctions in the control unit, even during programming
- → Switch off ignition before disconnecting the control unit.
- → Make sure that the power supply is not interrupted during programming/coding.
- → Connect the battery charger with at least > current 90 A to the vehicle battery.
Information
The PIWIS Tester instructions take precedence since the description may be different with later Tester releases.
The procedure described here has been structured in general terms. Different text or additional information may appear on the PIWIS Tester.
- Connect the Tester to the vehicle and start it. Switch on ignition.
- Select the vehicle type if required.
- Select the Driver/Passenger seat memory control unit in the overview. Press F12 to continue. The message "Create Vehicle Analysis Log (VAL)?" appears. Press F11 to continue.
- Coding/programming must be selected.
- Automatic coding must now be selected. Press F12 to continue.
- The Tester displays the message: Coding was completed successfully.
Information
For some equipment variants, standardisation must be performed on both the driver's side and passenger's side.
- Maintenance/repairs must now be selected.
- Standardise seat motors must be selected. F12 and start with F8.
- Read and follow the instructions and information on the Tester. Perform procedure according to menu guidance.
- Read out the fault memory, correct faults that are stored if necessary and clear the fault memory.
- Exit the diagnostic application. Switch off ignition. Disconnect the Tester from the vehicle.