Home >> Porsche >> 2021 >> Macan Base >> Repair and Diagnosis >> General Information >> Heating, Ventilation & A/C (HVAC) >> 8X Air Conditioning - General -- 95B - MACAN (95B) >> WM, 8X00IN - Technical Values - Air Conditioning >> Technical Values - Refrigerant Lines >> Tightening Torques For Refrigerant Lines

Tightening Torques For Refrigerant Lines

Location Description Type Basic value Tolerance
Refrigerant lines to air-conditioning compressor   Tightening torque 20 Nm (15 ftlb.)  
Refrigerant line to expansion valve M8 x 35 Tightening torque 12 Nm (9 ftlb.)  
Refrigerant lines to condenser M6 x 25 Tightening torque 9 Nm (6.5 ftlb.)  
Refrigerant lines to connection point in front left wheel housing M8 x 28 Tightening torque 12 Nm (9 ftlb.)  
Refrigerant line holder to engine M6/section of line from evaporator to compressor Tightening torque 9 Nm (6.5 ftlb.)  
Refrigerant lines to condenser connection point M6 x 25 Tightening torque 8 Nm (6 ftlb.)  
Refrigerant line holder to double clamp for refrigerant lines Tapping screw Tightening torque 4.5 Nm (3.25 ftlb.)  
Refrigerant line holder to lock carrier   Tightening torque 2.5 Nm (1.75 ftlb.)