Safety Regulations For Extraction And Filling Systems
WARNING:
Incorrect handling of air conditioning servicing equipment.
- Unnecessary damage to the environment due to emerging refrigerant.
- → Before connecting the filling system to the air-conditioning system, make sure that the manual shut-off valves are closed.
- → Before disconnecting the filling system from the air-conditioning system, make sure that the process is complete so that no refrigerant can escape into the atmosphere.
- → After the purified refrigerant has been filled into an external compressed gas bottle from the filling system, the manual shut-off valves on the bottle and on the filling system should be closed.
- → Do not expose the filling system to moisture or use in a damp environment.
- → Shut off the power supply at the filling system before carrying out maintenance work.
- → An extension cable with cross-sectional area of at least 2.5 mm2 should be used only when absolutely necessary.
- → In the case of fire, the external bottle should be removed.
- → Fill the oil extracted from the air-conditioning system into a suitable closable container (the refrigerant oil contains small quantities of refrigerant).
- → The filling system must be secured to prevent it from rolling away.
- → Set down and use the air conditioning servicing equipment with refrigerant R1234yf only in cool, well-ventilated places.
- → Protect from heat and direct sunlight and do not set down and use in areas with temperatures above 50°C.
- → Do not set down and use in or near cellars or other lower-lying areas.
- → Only set down and use in areas with adequate air flow (complete air exchange at least once per hour in the workshop area and 3 times per hour in lower-lying areas, e.g. in assembly groups).