LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2021 >> 911 Targa 4 >> Repair and Diagnosis >> Suspension >> Electronic Suspension >> 43 Leveling System, Air Suspension, Damper Control 3.0L (Eng Code MDK.Ca) -- 992 - 911 CARRERA (992) >> WM, 430117 Bleeding And Filling The Level Control (Front Axle Lift System) >> Producing Filling Adapter >> Making Filling Adapter

Making Filling Adapter

Information 

You must first make a filling adapter in order to drain and fill hydraulic fluid.

Following use, the filling adapter can be kept for future repairs.

  1. Order pressure line for actuator at connection point in wheel housing (see PET). Do not use the pressure line installed in the vehicle!
  2. Cut the pressure line to suit the connection for the actuator >Cutting pressure line  .
G15519687Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Cutting pressure line