Home >> Porsche >> 2021 >> 911 Targa 4 >> Repair and Diagnosis >> Suspension >> Electronic Suspension >> 43 Leveling System, Air Suspension, Damper Control 3.0L (Eng Code MDK.Ca) -- 992 - 911 CARRERA (992) >> WM, 430117 Bleeding And Filling The Level Control (Front Axle Lift System) >> Bleeding And Filling The Level Control (Front Axle Lift System) >> Fill The Level Control

Fill The Level Control

WARNING: Toxic substances 
  • Danger of poisoning or suffocation 
  • Danger of burns to the eyes and skin 

    → Ventilate the work area well.

    → Never ingest or inhale.

    → Read specific information on the Hazard Sheet.

    → Wear personal protective gear.

    → Do not smoke, eat or drink in the work area.

  1. Prepare new hydraulic fluid for the prescribed system filling capacity.
    • 1st option  :>Filling capacity 160 ml + 5 ml  Fill hydraulic fluid into a measuring cup.
    • 2nd option  : Mark the original filling bottle (>Filling capacity 250 ml  ) with the dimensions x >Height 38 mm   > Marking filling bottle  . The volume in the filling bottle up to the mark corresponds to the prescribed system filling capacity.
    G15519691Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Marking filling bottle

  2. Submerge the filling adapter in the filling container (measuring cup or filling bottle) in such a way that no air is sucked in.
  3. Connect the PIWIS Tester  to the vehicle and start it. Switch on ignition.
  4. Close the doors and cover.
  5. Select Front axle lift → Drive links/checks → Lower front end (fill system  in the control unit overview and confirm the displayed message.
    WARNING: Moving components 
    • Danger of limbs being trapped or severed 

      → Do not reach into the danger area.

      → Secure the system to prevent it from being activated accidentally.

      → Keep third parties away from the danger area.

    Information 

    Check the following during the filling process:

    • Get a second worker to help with the filling process. 
    • The compressor is always activated when you press F8 to start the routine  >Time approx. 10 s  . The routine can be cancelled by pressing F8 again. 
    • The filling adapter must be continually submerged in the hydraulic fluid. No air must be sucked in. 
    • If filling using a filling bottle, the bottle must be held horizontally. 
  6. Start filling hydraulic fluid by pressing F8. Repeat this procedure until the prescribed system filling capacity (see See  ) is sucked in. The routine must then be cancelled by pressing F8 again.
  7. Disconnect the filling adapter from the separating coupling in the wheel housing.
  8. Connect the actuator pressure line -1-  to the separating coupling in the wheel housing.
    G15519692Courtesy of PORSCHE CARS NORTH AMERICA, INC.

    Separating coupling for front axle lift system

    1. 8.1 Tighten screw -2-  on holder.