Replacing Steering Column Lock
NOTE:
Voltage drop
- Irreparable damage to control unit
- Damage to control unit
- Fault entries in the control unit
- Control unit programming/coding is aborted
- Malfunctions in the control unit, even during programming/coding
- Switch off ignition before disconnecting the control unit.
- Make sure that the power supply is not interrupted during programming/coding.
- Connect the battery charger with at least > current 90 A to the vehicle battery.
Information
- All remote controls (keys) are required for teaching a DME, rear-end electronics (rear BCM), electronic steering lock (ELV) control unit for example, or for teaching remote controls (keys).
- Remote controls (keys) that are not taught during this teaching procedure will no longer be recognised by the vehicle.
Information
The > 9900 - PIWIS Tester 3 instructions take precedence since the description may be different with later Tester releases.
The procedure described here has been structured in general terms; different text or additions may appear in > 9900 - PIWIS Tester 3 .
- Connect the Tester to the vehicle and start it. Switch on ignition.
- Place original remote control (hand-held transmitter) in emergency start tray.
Emergency start tray
- Select the vehicle type if required.
- Select the Steering column lock control unit in the overview . Press F12 to continue. The message "Create Vehicle Analysis Log (VAL)?" appears. Press F11 to continue.
- Coding/programming must be selected.
- Automatic coding
must now be selected. Press F12
to continue.
- 6.1 The Tester displays the message: Coding was completed successfully.
- Go back to the overview.
- In the overview , press F7 to switch to the Additional menu .
- Engine immobiliser start-up
must be selected. Press F12
to continue.
- 9.1 Read and follow the instructions and information on the Tester.
- 9.2 Teach engine immobiliser according to menu guidance.
- 9.3 The Tester displays the message: Engine immobiliser taught successfully.
- Go back to the overview.
- Read out the fault memory , correct faults that are stored if necessary and clear the fault memory.
- Exit the diagnostic application. Switch off ignition. Disconnect the Tester from the vehicle.
- Lock, open and start the vehicle using all remote controls.