Removing Leakage Diagnosis Module: Overview
WARNING:
Highly inflammable or explosive materials
- Danger of fire or explosion
→ Avoid contact with hot parts or sources of ignition.
→ Use suction to remove ignitable vapours.
→ Attach warning sign in a clearly visible position.
→ Contain leaked media using non-flammable absorbent material and put it in a container designed for this purpose for disposal in accordance with local requirements.
→ Secure collection containers/vessels to prevent them from tipping over.
- Unscrew screws -1- and pull leakage diagnosis module -2- off the carbon canister -arrow- .
Leakage diagnosis module