Preparing Connection Areas Of Body For Installing The Roof Pillar
- Align the sealing surfaces and connections of the body.
- De-burr connection areas and prepare for welding.
- Prepare marked areas -A-
for bonding and resistance spot-welding.
> 5X00IN21 WORKING WITH BODY STRUCTURAL ADHESIVE PAH.071.781.00
Connection areas of the body
- Prepare marked area -B-
for applying a full weld using inert gas.
Connection areas of the body
- Prepare marked area -C-
for aluminium welding.
Connection areas of the body