Preparing Front Side Member (Front Section) For Installation
Information
The measuring point for taking measurements is on the floor front section. Given this, the floor front section must also be secured for taking measurements, otherwise there will be a gap.
- Position front side member (front section) using the straightening bracket
- Drill holes for blind rivets in areas -A and B-
through both sheet metal panels with > diameter 6.6 mm
Inner riveted joints
- Drill holes for blind rivets in areas -A and B-
through both sheet metal panels with > diameter 6.6 mm
.
Outer riveted joints
- Drill bore holes for blind rivets through both sheet metal plates from the outside using > diameter 6.6 mm
.
Upper riveted joints
- Drill holes for blind rivets in areas -A and B-
through both sheet metal panels with > diameter 6.6 mm
.
Lower riveted joints
- Drill bore hole for blind rivets through both sheet metal plates from the outside using > diameter 6.6 mm
.
Bore
- Drill bore hole for blind rivets through both sheet metal plates from the outside using > diameter 6.6 mm
.
Bore
- Remove front longitudinal member (front section) and floor front section.
- Prepare marked areas -A-
on the front longitudinal member (front section) for bonding and riveting.
> 5X00IN21 WORKING WITH BODY STRUCTURAL ADHESIVE PAH.071.781.00
Bonding areas
- Prepare front longitudinal member (front section) in area -B-
for aluminium MiG welding.
Bonding areas