Preparing Wing Connection Panel For Installation
- Fit wing connection panel and secure it to the body.
- Drill holes for BLIND RIVETS -A and B-
through both sheet metal panels.
Blind rivets
A > Diameter 4.1 mm B > Diameter 6.6 mm - Countersink holes for countersunk BLIND RIVETS -A-
.
Countersunk blind rivets
- Remove wing connection panel.
- Prepare wing connection panel for bonding and riveting.
> 5X00IN21 WORKING WITH BODY STRUCTURAL ADHESIVE PAH.071.781.00
Joint areas