LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2021 >> 718 Boxster S, Automatic DCT Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 24 (48 Steering 2.0L -- 982 - BOXSTER/CAYMAN) >> WM, 480855 Replacing ELV (Steering Lock) Control Unit >> Replacing ELV Control Unit

Replacing ELV Control Unit

WARNING: This page is about a different variant/trim than selected.

NOTIFICATION 

Voltage drop 

  1. Switch off ignition and replace the ELV control unit.

    > WM, 480819 REMOVING AND INSTALLING STEERING LOCK 

    Information 

    The > 9818 - PIWIS Tester II  instructions take precedence and in the event of a discrepancy, these are the instructions that must be followed.

    A discrepancy may arise with later software versions for example.

    Information 

    All remote controls (keys) are required in order to teach a control unit or remote control (key).

    Remote controls (keys) that are not taught during the teaching procedure will no longer be recognized by the vehicle.

  2. > 9818 - PIWIS Tester II  must be connected to the vehicle before starting it. Switch on ignition.
  3. Select the required vehicle type.
  4. In the control unit overview,  press to call up the Additional menu. 

    When the question "Create Vehicle Analysis Log (VAL)?" appears, either press to create a VAL or press if you do not want to create a VAL.

  5. Engine immobilizer start-up  must be selected. Press to continue.
  6. Enter the PPN user name and password. Press to continue.
  7. The vehicle identification number (VIN) is displayed. Make changes if necessary and press to confirm.
  8. Enter the repair order number and press to confirm.
  9. Follow the instructions on the Tester and carry out the process.
  10. Once the teaching process is completed successfully, the Tester shows the following status:

    BCM front: taught

    BCM rear: taught

    ELV: taught

    DME: taught

    Number of keys taught: x

    Press to continue.

  11. Read and follow the instructions displayed on the Tester. Press to continue.
  12. Read out fault memory and erase it if necessary.
  13. Exit the diagnostic application.
  14. Switch off the ignition.
  15. > 9818 - PIWIS Tester II  must then be disconnected from the vehicle.
  16. Lock and unlock the vehicle and start the engine using all remote controls.