Removing Directional-Control Valve For Thermal Management
WARNING: This page is about a different variant/trim than selected.
Installation position of directional-control valve for thermal management
WARNING:
Caustic fluids
- Danger of chemical burns
- → Wear personal protective gear.
- → Ensure that there is good ventilation.
- → Avoid contact with caustic fluid.
- → If you do come into contact, wash off immediately with plenty of warm water and contact a doctor if necessary.
- Remove holder -2-
.
- 1.1 Unscrew and remove fastening screw -1- .
- 1.2 Move holder -2- with electric line -3- aside.
- Pull coolant hose -5-
off the directional-control valve.
- 2.1 Loosen spring band clamp -4- on the coolant hose -5- .
- 2.2 Pull off coolant hose -5- .
Removing holder and coolant hose
- Remove directional-control valve -1-
.
- 3.1 Pull vacuum line -2- off the directional-control valve -1- .
- 3.2 Unscrew fastening screws -3- .
- 3.3 Remove directional-control valve -1- .
Directional-control valve