Insulation Fault Finding
WARNING:
Incorrect handling of high-voltage components
- Electric shock
- Short circuit
- Fire
- Explosion
→ Only appropriately trained and authorised persons are permitted to work on high-voltage vehicles and components.
→ Required qualification: High voltage technician or high voltage expert.
→ Observe national requirements and legislation for this work.
→ Always use insulated tools, e.g. > VAS 6883 - Insulated Tool Set when working on these components.
→ Observe general warning notes for working on the high-voltage system.
> 2X00IN GENERAL WARNING NOTES FOR WORKING ON THE HIGH-VOLTAGE SYSTEM
Information
- Use > 9900 - PIWIS Tester 3 with > VAS 6558A - high-voltage testing module and the test adapters > VAS 6558/9-6A - high-voltage test adapter , > VAS 6558A/30 - HV test adapter , > VAS 6558A/38 - HV test adapter , > VAS 6558A/40 - HV test adapter to perform the measurements for the insulation test .