Remove E-Box
WARNING: This page is about a different variant/trim than selected.
WARNING:
Incorrect handling of high-voltage components
- Electric shock
- Short circuit
- Fire
- Explosion
→ Only appropriately trained and authorized persons may work on high-voltage vehicles and components.
→ Required qualification: High voltage technician or high voltage expert.
→ Observe national requirements and legislation for this work.
→ Always use insulated tools, such as an > VAS 6883 - insulated tool set when working on these parts.
→ Observe general warning notices for working on the high-voltage system.
> WM, 2X00IN GENERAL WARNING NOTES FOR WORKING ON THE HIGH-VOLTAGE SYSTEM
- Perform tests for verifying absence of electric charge and insulation resistance tests using > VAS 6558A - High-voltage testing module
, > VAS 6558/9-7 - High-voltage test adapter HVR 40
and > 9900 - PIWIS Tester 3
.
> 270803 PERFORMING MEASUREMENTS ON THE HIGH-VOLTAGE BATTERY
- Loosen retaining frame at the top -2- .
- Remove pressure accumulator with load distributor plate and retaining frame.
- 3.1 Unscrew fastening screws -5-
.
Fastening screws on pressure accumulator, bottom
- 3.2 Unscrew fastening screws -6-
.
Fastening screws on retaining frame, bottom
- 3.3 Remove load distributor plate together with lower bar from the high-voltage battery and set it aside.
- 3.4 Remove retaining frame together with the pressure accumulator from the high-voltage battery and set it aside.
- 3.1 Unscrew fastening screws -5-
.
- Remove E-box.
- 4.1 Unscrew fastening screws using > VAS 691 003A - High-voltage tool set TORX®
. The exposed threads must be cleaned. Replace micro-self-locking screws.
Fastening screws on E-box
- 4.2 > 9924 - Centring pins-3-
must now be screwed into the free bores.
Centring pins on E-box
- 4.3 Unscrew and remove fastening screw -4-
.
Replace micro-self-locking screw.
Loosening E-box
- 4.4 Carefully disconnect E-box from the high-voltage battery.
- 4.1 Unscrew fastening screws using > VAS 691 003A - High-voltage tool set TORX®
. The exposed threads must be cleaned. Replace micro-self-locking screws.