Removing Directional-Control Valve
- Remove air inlet housing cover -1-
.
Air inlet housing cover
- 1.1 Unscrew nuts -2- and remove air inlet housing cover -1- .
WARNING: Hot fluid- Danger of scalding
- → Avoid contact with hot fluid.
- → Wear personal protective gear.
- Remove directional-control valve -1-
.
Directional-control valve
- 2.1 Clamp coolant hoses using > 3094 - hose clamp .
- 2.2 Release and disconnect electric plug connection -2- .
- 2.3
Loosen spring band clamps -3-
using >
VAS 6890 - spring band clamp pliers
and disconnect coolant hoses from the directional-control valve -1-
.
- 2.3.1 Close off line connections using suitable stoppers.
- 2.4 Loosen nuts -4- and remove directional-control valve -1- .